Technical Data
Screw Air Compressor Specifications
Complete technical parameters for the Ares ARS series — 15 standard models from 7.5 kW (10 hp) to 250 kW (350 hp), plus six integrated laser-cutting air stations. All figures are listed in both metric and imperial units.

Table 1
ARS series screw air compressor — full range
Direct-coupled, VFD-controlled rotary screw compressors, 380 V/50 Hz (other voltages and frequencies on request). Pressure is given in bar and psi.
| Parameter | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model | ARS-10HP | ARS-15HP | ARS-20HP | ARS-30HP | ARS-50HP | ARS-75HP | ARS-100HP | ARS-125HP | ARS-150HP | ARS-175HP | ARS-200HP | ARS-250HP | ARS-285HP | ARS-300HP | ARS-350HP |
| Motor powerkW — IEC rating | 7.5 | 11 | 15 | 22 | 37 | 55 | 75 | 90 | 110 | 132 | 160 | 185 | 200 | 220 | 250 |
| Motor powerhp — nominal, per model | 10 | 15 | 20 | 30 | 50 | 75 | 100 | 125 | 150 | 175 | 200 | 250 | 285 | 300 | 350 |
| Free air delivery (FAD)m³/min | 1.1 | 1.5 | 2.3 | 3.6 | 6.2 | 10 | 13.4 | 16.2 | 20.5 | 24.3 | 28.7 | 32 | 35 | 40 | 43 |
| Free air delivery (FAD)cfm — converted | 39 | 53 | 81 | 127 | 219 | 353 | 473 | 572 | 724 | 858 | 1,014 | 1,130 | 1,236 | 1,413 | 1,519 |
| Rated working pressurebar | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 |
| Rated working pressurepsi — converted | 116 | 116 | 116 | 116 | 116 | 116 | 116 | 116 | 116 | 116 | 116 | 116 | 116 | 116 | 116 |
| Rated working pressureMPa | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 |
| Noise leveldB(A) | 60±3 | 65±3 | 65±3 | 68±3 | 70±3 | 72±3 | 75±3 | 78±3 | 80±3 | 80±3 | 80±3 | 80±3 | 80±3 | 80±3 | 80±3 |
| Transmissiondrive type | Direct linkage | Direct linkage | Direct linkage | Direct linkage | Direct linkage | Direct linkage | Direct linkage | Direct linkage | Direct linkage | Direct linkage | Direct linkage | Direct linkage | Direct linkage | Direct linkage | Direct linkage |
| Power supplycustomizable on request | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz | 380 V / 50 Hz |
| Starting modecontrol | VFD soft start | VFD soft start | VFD soft start | VFD soft start | VFD soft start | VFD soft start | VFD soft start | VFD soft start | VFD soft start | VFD soft start | VFD soft start | VFD soft start | VFD soft start | VFD soft start | VFD soft start |
| Overall dimension — Lmm | 800 | 1,150 | 1,150 | 1,060 | 1,200 | 1,800 | 1,800 | 1,800 | 2,400 | 2,400 | 2,400 | 3,200 | 3,200 | 3,200 | 3,200 |
| Overall dimension — Wmm | 570 | 730 | 730 | 850 | 950 | 1,250 | 1,250 | 1,250 | 1,470 | 1,470 | 1,470 | 1,980 | 1,980 | 1,980 | 1,980 |
| Overall dimension — Hmm | 810 | 990 | 990 | 1,160 | 1,260 | 1,570 | 1,570 | 1,570 | 1,840 | 1,840 | 1,840 | 2,150 | 2,150 | 2,150 | 2,150 |
| Overall dimension L×W×Hinch — converted | 31.5×22.4×31.9 | 45.3×28.7×39 | 45.3×28.7×39 | 41.7×33.5×45.7 | 47.2×37.4×49.6 | 70.9×49.2×61.8 | 70.9×49.2×61.8 | 70.9×49.2×61.8 | 94.5×57.9×72.4 | 94.5×57.9×72.4 | 94.5×57.9×72.4 | 126×78×84.6 | 126×78×84.6 | 126×78×84.6 | 126×78×84.6 |
| Net weightkg | 120 | 206 | 206 | 280 | 360 | 1,010 | 1,090 | 1,150 | 1,670 | 1,790 | 1,910 | 2,490 | 2,590 | 2,700 | 2,800 |
| Net weightlb — converted | 265 | 454 | 454 | 617 | 794 | 2,227 | 2,403 | 2,535 | 3,682 | 3,946 | 4,211 | 5,490 | 5,710 | 5,952 | 6,173 |
| Air outletinch / DN | G½ | G¾ | G¾ | G1 | 1½" | 1½" | 2" | 2" | DN65 | DN65 | DN65 | DN80 | DN80 | DN80 | DN80 |
Rows marked converted are calculated from the metric values (1 m³/min = 35.31 cfm · 1 bar = 14.504 psi · 1 kW = 1.34 hp · 1 in = 25.4 mm · 1 kg = 2.205 lb) and are shown for reference only; the metric figures are the governing ratings. Nominal horsepower corresponds to the model designation. Standard rated pressure is 8 bar (116 psi, 0.8 MPa); 13 bar (189 psi) and 16 bar (232 psi) versions are available as the -1.3 MPa and -1.6 MPa designations listed in our CE certificate. Noise figures are measured at 1 m under standard test conditions.
Table 2
Integrated screw air stations for laser cutting
Complete compressed-air stations matched to fiber laser cutters from 1,000 W to 40,000 W. Rated pressure 16 bar / 232 psi — the pressure band required for clean, burr-free cutting on thick plate.
| Parameter | ||||||
|---|---|---|---|---|---|---|
| Model | ARS-20HPall-in-one | ARS-20HPsplit | ARS-30HPall-in-one | ARS-30HPsplit | ARS-30HP-XFall-in-one | ARS-50HP-XFall-in-one |
| Matched laser cutterW — laser output power | 1000–4000 | 1000–4000 | 6000–8000 | 6000–8000 | 12000–20000 | 20000–40000 |
| Screw air compressor | ||||||
| Motor powerkW | 15 | 15 | 22 | 22 | 22 | 37 |
| Motor powerhp — nominal | 20 | 20 | 30 | 30 | 30 | 50 |
| Rated pressureMPa | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 |
| Rated pressurebar | 16 | 16 | 16 | 16 | 16 | 16 |
| Rated pressurepsi — converted | 232 | 232 | 232 | 232 | 232 | 232 |
| Free air deliverym³/min | 1.28 | 1.28 | 2.28 | 2.28 | 2.28 | 3.6 |
| Free air deliverycfm — converted | 45 | 45 | 81 | 81 | 81 | 127 |
| Air treatment train | ||||||
| Refrigerated dryerm³/min | 2 | 2 | 3.8 | 3.8 | 3.8 | 3.8 |
| Moisture separatorm³/min | 2 | 2 | 2.5 | 2.5 | 3.8 | 3.8 |
| 4-stage precision filteraccuracy / residual oil | 0.01 µm / 0.001 ppm | 0.01 µm / 0.001 ppm | 0.01 µm / 0.001 ppm | 0.01 µm / 0.001 ppm | 0.01 µm / 0.001 ppm | 0.01 µm / 0.001 ppm |
| 4-stage precision filterelement service life | 6,000 h | 6,000 h | 6,000 h | 6,000 h | 6,000 h | 6,000 h |
| Air storage tankm³ | 0.48 | 0.6 | 0.6 | 1 | 1 | 0.6 + 0.6 |
| Micro-thermal adsorption dryerm³/min | — | — | — | — | 2.6 | 3.8 |
| Micro-thermal adsorption dryerpressure dew point °C | — | — | — | — | -20 to -40 | -20 to -40 |
| System | ||||||
| Overall dimension L×W×Hmm | 1600×780×1700 | 2500×750×2150 | 1850×900×1850 | 3000×850×2250 | 4000×850×2250 | 5000×950×2150 |
| Overall dimension L×W×Hinch — converted | 63×30.7×66.9 | 98.4×29.5×84.6 | 72.8×35.4×72.8 | 118.1×33.5×88.6 | 157.5×33.5×88.6 | 196.9×37.4×84.6 |
| Net weightkg | 510 | 530 | 780 | 850 | 1,050 | 1,350 |
| Net weightlb — converted | 1,124 | 1,168 | 1,720 | 1,874 | 2,315 | 2,976 |
ARS-30HP-XF and ARS-50HP-XF include a micro-thermal adsorption dryer (heatless regenerated, purge-loss controlled) achieving a pressure dew point of −20 °C to −40 °C (−4 °F to −40 °F) for high-precision cutting heads. The all-in-one configuration ships as a single pre-piped and pre-wired skid; the split configuration separates the compressor from the tank and treatment train where floor space is restricted.
Reference
Pressure and unit conversions
Use these factors to convert any figure in the tables above. Our sales team can supply a datasheet in your preferred unit system on request.
1 bar = 100 kPa = 14.504 psi1 MPa = 10 bar = 145.04 psi8 bar = 116 psi · 16 bar = 232 psi
1 m³/min = 35.31 cfm1 cfm = 0.0283 m³/min1 m³/min = 60 m³/h = 16.67 L/s1 kW = 1.341 hp1 hp = 0.7457 kWModel suffixes denote nominal hp.
1 in = 25.4 mm1 mm = 0.0394 inOutlets: G½ ≈ 0.5 in, DN80 ≈ 3 in.
1 kg = 2.205 lb1 lb = 0.4536 kg°C = (°F − 32) × 5/9°F = °C × 9/5 + 32Dew point −40 °C = −40 °F.
Ambient conditions for all ratings: 20 °C inlet air and 1 bar(a) absolute inlet pressure, unless stated otherwise. Capacities vary with discharge pressure, ambient temperature and altitude — contact us for site-specific selection.
How to read the tables
Selecting the right model
1. Start from air demand
Total the cfm (or m³/min) required by all simultaneous tools, then add 15–25 % headroom for leakage and future expansion. Pick the model whose FAD meets that figure.
2. Confirm the pressure band
Most general industrial work runs at 8 bar (116 psi). Laser cutting and some high-pressure processes need 16 bar (232 psi) — see Table 2.
3. Check footprint and outlet
Use the dimension and outlet rows to confirm the unit fits the plant room and matches your existing pipework. Split configurations are available for tight spaces.
CE conformity
ARS series screw air compressors are covered by CE Attestation of Conformity No. M.2025.206.C123607 (UDEM International Certification, Türkiye) issued under 2006/42/EC Machinery Directive and 2014/30/EU EMC Directive. Report No. Ares-250729. Valid until 30 July 2030.
Next step
Need a datasheet for a specific model?
Tell us the model, the pressure band and your unit preference — we will send a model-specific datasheet, dimensional drawing and quotation.